MCQ Mojo
access_time
menu
Quiz
Web Stories
CBSE
arrow_drop_down
MCQ Questions for CBSE Class 12 with Answers
MCQ Questions for CBSE Class 11 with Answers
MCQ Questions for CBSE Class 10 with Answers
MCQ Questions for CBSE Class 9 with Answers
MCQ Questions for CBSE Class 8 with Answers
MCQ Questions for CBSE Class 7 with Answers
MCQ Questions for CBSE Class 6 with Answers
MCQ Questions for CBSE Class 5 with Answers
MCQ Questions for CBSE Class 4 with Answers
MCQ Questions for CBSE Class 3 with Answers
MCQ Questions for CBSE Class 2 with Answers
MCQ Questions for CBSE Class 1 with Answers
CBSE
arrow_drop_down
MCQ Questions for CBSE Class 12 with Answers
MCQ Questions for CBSE Class 11 with Answers
MCQ Questions for CBSE Class 10 with Answers
MCQ Questions for CBSE Class 9 with Answers
MCQ Questions for CBSE Class 8 with Answers
MCQ Questions for CBSE Class 7 with Answers
MCQ Questions for CBSE Class 6 with Answers
MCQ Questions for CBSE Class 5 with Answers
MCQ Questions for CBSE Class 4 with Answers
MCQ Questions for CBSE Class 3 with Answers
MCQ Questions for CBSE Class 2 with Answers
MCQ Questions for CBSE Class 1 with Answers
Quiz
Quiz
/
Metrology Engineering Gate & PSU MCQ Questions With Answers
1.
Sine bar is used to measure an angle upto.......... degrees.
30
45
60
90
2.
Which of the following is a characteristic of End standard?
accuracy of ± 0.2 mm
accuracy of ± 0.050 mm
accuracy of ± 0.001 mm
accuracy of ± 1.00 mm
3.
What it indicates?
More precise and more accurate
No precise but accurate
accurate but not precise
neither precise nor accurate
4.
Why study Limit system? Which below statement does not reason the purpose of studying limit system
Exact size is impossible to achieve
Establish boundaries within which deviation from perfect form is allowed but still the design intent is fulfilled
Enable removability of components during assembly
Enable replace ability of components during assembly
5.
_________ refers to the closeness of 2 or more measurements to each other.
Precision
Accuracy
Togetherness
Standard Value
6.
Which of the following error is not a systematic error?
Error induced due to stylus pressure
Instrument location errors
Error due to parallax
Error due to play in the instrument’s linkages
7.
Dimension 100 H7 indicates
Hundred houses on 7th cross
100 horses in 7 rows
Basic size of 100 , H fundamental deviation for Hole and 7 IT Grade
Basic size of 100 , H fundamental deviation for shaft and 7 IT Grade
8.
The maximum and minimum permissible sizes within which the actual size of a component lies are called ___________.
Limits
Boundary
Allowance
Basic sizes
9.
What is bilateral tolerance?
Total tolerance is in 1 direction only
Total tolerance is in both the directions
May or may not be in one direction
Tolerance provided all over the component body
10.
It is the susceptibility of a measurement device to have its indicators converted into meaningful numbers.
· Readability
· Precision
· Inspection
· Error
11.
If the tolerance is allowed on one side of the basic size it is called _____________ tolerance.
Unit
Undivided
Unilateral
Under
12.
The study of scientific metrology deals with
accuracy and methods of measurement
standard specifications
theories related to nature
all of the above
13.
What is the main purpose of Wringing of slip gauges?
Increase length between mating slips
Reduce length between mating slips
Remove air-gap between mating slips
Align mating slips
None of the above
14.
The desirable static characteristics of a measuring system are
Accuracy and resproducibility
Accuracy, sensitivity and reproducibility
Drift and dead zone
Static error
15.
In the Standard IS 919 of limits & Fits; there are _______ number of fundamental deviations.
20
100
28
25
16.
In Limits, Fits and Engineering tolerances; What is expansion of the acronym MMC?
My Machine Campaign
Medium Material Condition
Most Material Cut
Maximum Material Condition
17.
Which is not a type of tolerance?
Quadrilateral
Bilateral
Unilateral
18.
Gambar tersebut merupakan toleransi apa?
Toleransi Bilateral
Toleransi Unilateral
Toleransi Limit Dimensi
19.
If the instrument is used in wrong manner while application, then it will results in
Systematic error
Instrument error
Random error
Environmental error
20.
From which category, sigma comparator belongs?
Optical comparator
mechanical comparator
mechanical-optical comparator
electric comparator
Report Question